Vigilancia colonoscópica posterior a la polipectomía: resumen

01.10.2021
Nadzór endoskopowy po usunieciu polipów z jelita grubego. Omówienie wytycznych European Society of Gastrointestinal Endoscopy 2020
Mateusz Szmit (MD), Marek Bugajski (MD, PhD), Jarosław Reguła (MD)
A partir de: C. Hassan, G. Antonelli, J.M. Dumonceau, J. Regula, M. Bretthauer, S. Chaussade, E. Dekker, M. Ferlitsch, A. Gimeno Garcia, R. Jover, M. Kalager, M. Pellisé, C. Pox, L. Ricciardiello, M. Rutter, L.M. Helsingen, A. Bleijenberg, C. Senore, J.E. van Hooft, M. Dinis Ribeiro, E. Quintero, Post polypectomy colonoscopy surveillance: European Society of Gastrointestinal Endoscopy (ESGE) guideline – update 2020, Endoscopy, 2020, 52: 687-700

A recordar

Una mala preparación intestinal para la prueba (p. ej. <6 ptos. en la BBPS) supone una indicación para repetir la colonoscopia en un año.

Después de una resección mucosectomía en fragmentos (pEMR) de lesiones ≥10 mm en el colon, la primera colonoscopia de control se debe realizar a los 3-6 meses, y la siguiente 12 meses después (15-18 meses después de la primera colonoscopia con polipectomía).

Tras las resecciones completas de 1-4 adenomas de <10 mm con displasia de bajo grado (independientemente del componente velloso) y las resecciones de un pólipo serrado <10 mm sin rasgos de displasia, la siguiente colonoscopia se debe realizar a los 10 años.

La primera colonoscopia de control se debe realizar 3 años después de la resección completa de las lesiones que requieren vigilancia, es decir:
1) ≥1 adenomas ≥10 mm o con displasia de grado alto, o
2) ≥5 adenomas, o
3) un pólipo serrado ≥10 mm o con displasia.

Si en la primera colonoscopia de control no se observan lesiones que requieran vigilancia, se sugiere realizar la siguiente 5 años después, y si tampoco se observa nada en ella, realizar otra colonoscopia a los 10 años.

Si se observan lesiones que requieran vigilancia en la colonoscopia de control, ya sea la primera o una de las siguientes, se sugiere realizar otra 3 años después.

Bibliografía:

1. Atkin W., Wooldrage K., Brenner A. y cols., Adenoma surveillance and colorectal cancer incidence: a retrospective, multicentre, cohort study, Lancet Oncol., 2017; 18: 823-834
2. Szmit M., Bugajski M., Kamiński M.F., Przygotowanie jelita grubego do kolonoskopii. Omówienie wytycznych European Society of Gastrointestinal Endoscopy 2019, Med. Prakt., 2020; 3: 68-77
3. Sakata S., McIvor F., Klein K. y cols., Measurement of polyp size at colonoscopy: a proof-of-concept simulation study to address technology bias, Gut, 2018; 67: 206-208
4. Djinbachian R., Dubé A.-J., Durand M. y cols., Adherence to post-polypectomy surveillance guidelines: a systematic review and meta-analysis, Endoscopy, 2019; 51: 673-683
5. Hong S., Suh M., Choi K.S. y cols., Guideline adherence to colonoscopic surveillance intervals after polypectomy in Korea: results from a nationwide survey, Gut Liver, 2018; 12: 426-432
6. Lee J.K., Jensen C.D., Levin T.R. y cols., Long-term risk of colorectal cancer and related death after adenoma removal in a large, community based population, Gastroenterology, 2020; 158: 884-894
7. Ferlitsch M., Moss A., Hassan C. y cols., Colorectal polypectomy and endoscopic mucosal resection (EMR): European Society of Gastrointestinal Endoscopy (ESGE) Clinical Guideline, Endoscopy, 2017; 49: 270-297
8. Wieszczy P., Kaminski M.F., Franczyk R. y cols., Colorectal cancer incidence and mortality after removal of adenomas during screening colonoscopies, Gastroenterology, 2020; 158: 875-883
9. He X., Hang D., Wu K. y cols., Long-term risk of colorectal cancer after removal of conventional adenomas and serrated polyps, Gastroenterology, 2020; 158: 852-861
10. Click B., Pinsky P.F., Hickey T. y cols., Association of colonoscopy adenoma findings with long-term colorectal cancer incidence, JAMA, 2018; 319: 2021-2031
11. Jover R., Bretthauer M., Dekker E. y cols., Rationale and design of the European Polyp Surveillance (EPoS) trials, Endoscopy, 2016; 48: 571-578
12. Holme O., Bretthauer M., Eide T.J. y cols., Long-term risk of colorectal cancer in individuals with serrated polyps, Gut, 2015; 64: 929-936
13. Cross A.J., Robbins E.C., Pack K. y cols., Long-term colorectal cancer incidence after adenoma removal and the effects of surveillance on incidence: a multicentre, retrospective, cohort study, Gut, 2020; 69: 1645-1658
14. Grover S., Kastrinos F., Steyerberg E.W. y cols., Prevalence and phenotypes of APC and MUTYH mutations in patients with multiple colorectal adenomas, JAMA, 2012; 308: 485-492
15. Gupta S., Provenzale D., Regenbogen S.E. y cols., NCCN Guidelines insights: genetic/familial high-risk assessment: colorectal, version 3.2017, J. Natl. Compr. Canc. Netw., 2017; 15: 1465-1475
16. van Leerdam M.E., Roos V.H., van Hooft J.E. y cols., Endoscopic management of polyposis syndromes: European Society of Gastrointestinal Endoscopy (ESGE) Guideline, Endoscopy, 2019; 51: 877-895
17. Moss A., Williams S.J., Hourigan L.F. y cols., Long-term adenoma recurrence following wide-field endoscopic mucosal resection (WF-EMR) for advanced colonic mucosal neoplasia is infrequent: results and risk factors in 1000 cases from the Australian Colonic EMR (ACE) study, Gut, 2015; 64: 57-65
18. Belderbos T.D.G., Leenders M., Moons L.M.G. y cols., Local recurrence after endoscopic mucosal resection of nonpedunculated colorectal lesions: systematic review and meta-analysis, Endoscopy, 2014; 46: 388-402
19. Shahid M.W., Buchner A.M., Heckman M.G. y cols., Diagnostic accuracy of probe-based confocal laser endomicroscopy and narrow band imaging for small colorectal polyps: a feasibility study, Am. J. Gastroenterol., 2012; 107: 231-239
20. Arbib O.S., Zemser V., Weissman Y.L. y cols., Risk of advanced lesions at the first follow-up colonoscopy after polypectomy of diminutive versus small adenomatous polyps of low-grade dysplasia, Gastrointest. Endosc., 2017; 86: 713–721

Volver al artículo principal: Guías: vigilancia colonoscópica posterior a la polipectomía